Sprinkler Hanger

Sprinkler Hanger


The Sprinkler Hanger offers a robust solution for securely mounting sprinkler systems. Engineered with durability and functionality in mind, this hanger ensures reliable support for sprinkler pipes in various environments. Its innovative design facilitates easy installation, saving time and effort during setup. With a focus on safety and efficiency, the Sprinkler Hanger provides peace of mind, knowing that the sprinkler system is securely mounted and ready to perform effectively in case of emergencies. Whether for residential, commercial, or industrial applications, this hanger is a dependable choice for maintaining fire protection systems.

Roset Plate

Roset Plate is used along with sprinklers to hide Unfinished and untidy surface beneath the wall. The place gives a neat and decorative value.

  • Product Material : Mild steel
  • Material will be available on request SS-304 and SS-316

Rubber casing for smooth support

The rubber makes an extra grip on the pipe. It also absorb any vibrations or noise due to the flow inside the pipe and stops them from going to the nuts and bolts and they remain tight and secure.

Dimension Chart

Reference Nominal Pipe Size Rod Size Width X Thickness mm
mm inch in mm mm
CSC-101 15 1/2″ 8/10 25 X 1.2
CSC-102 20 3/4″ 8/10 25 X 1.2
CSC-103 25 1″ 8/10 25 x 1.5
CSC-104 32 11/4″ 8/10 25 x 1.5
CSC-105 40 11/2″ 8/10 25 x 1.5
CSC-106 50 2″ 8/10 25 X 2.0
CSC-107 65 21/2″ 10 25 X 2.0
CSC-108 80 3″ 10 25 x 2.5
CSC-109 100 4″ 12 25 x 2.5
CSC-110 125 5″ 12 30 x 3.0
CSC-111 150 6″ 16 30 x 3.0
CSC-112 200 8″ 16 30 x 3.0
CSC-113 250 10″ 16 30 x 4.0
CSC-114 300 12″ 16 30 x 4.0

 

Installation Picture

  • Make holes of the required diameter As per the outer dia of the fastener. Clear the debris making clean holes for the fastener. Insert 3 leaf bold shield fastener in to the holes
  • Insert rods into fasteners holes and tighten so that The leaf at the top end opens and position the fasteners Firmly in the ceiling. Put nut washer in the rods at the ceiling level So that they do not move from their tightened position.
  • Put sprinkler clamps into the pipe in requires distance and lift Up with support to the rods attached to the fasteners above.
  • Tighten the clamps with nut washer put on both the ends of the Clamp hole.
  • Take out the support after the sprinkler clamps have been Tightened enough.

Application Area

  • Plumbing
  • Sanitation
  • Fire Fighting
  • Electric and Power lines
  • Air Conditioning
  • Gas,oil, Chimney Irrigation areas
  • Solar plants
  • Parkings
  • Factories and Plants
  • Households
  • Housing complexes
  • Hospitals
  • Shopping Malls
  • Pharmaceuticals
  • Gardens and Landscapes