Clevis Hanger

Clevis Hanger


IntelloTech The Clevis Hanger is a versatile and reliable solution for suspending pipes, conduits, and other equipment from overhead structural elements. Its design features a clevis pin secured by a cotter pin, offering sturdy support and easy adjustment. Engineered for durability and strength, Clevis Hangers are commonly used in HVAC, plumbing, and electrical installations. They provide stability and flexibility, allowing for the precise positioning of hanging components. With various sizes and load capacities available, Clevis Hangers accommodate a wide range of applications, making them indispensable in construction and industrial settings.

Rubber casing for smooth support

The rubber makes an extra grip on the pipe.It also absorbs any vibrations and noise due to flow inside the pipes and does not let them pass to the nuts and bolts which do not become loose as a result.

  • Product Material : Mild steel
  • Material will be available on request SS-304 and SS-316

Unique design

Element of yoke on outside of lower strap barring the yoke from sliding toward the centre of the bolt resulting in minimising of bending of the bolt.

 

Dimension Chart

Reference Nominal Pipe Size Rod Size Width X Thickness
mm inch
CCH-101 25 1″ 8 20 X 2
CCH-102 32 11/4″ 8 20 X 2
CCH-103 40 11/2″ 8 20 X 2
CCH-104 50 2″ 8 20 X 2
CCH-105 65 21/2″ 10 20 X 2
CCH-106 80 3″ 12 25 X 2.5
CCH-107 100 4″ 12 25 X 2.5
CCH-108 125 5″ 12 30 X 3
CCH-109 150 6″ 16 30 X 3
CCH-110 200 8″ 16 30 X 3

Installation Picture

  • Make holes of the required diameter as per the outer idea of the fastener. Clear the debris making clean holes for the fastener. Insert 3 leaf bolt shield fastener into the holes.
  • Insert rods into fasteners holes and tighten so that the leaf at the top ens opens and position the fasteners firmly in the ceiling.Put nut washer in the rods at the ceiling level so that they do not move from their tightened position.
  • Put Clevis hanger clamps into the pipe in requires distance and lift up with support to the rods above. Tighten the clamp to the rods by putting nut washer at both ends of the clamp hole.
  • Take out the support after the clevis hanger clamps have been tightened enough.
  • The pipe can also be slid through the already installed row of clevis hangers since the pendulum action absorbs any disturbance caused during the sliding process.

Application Area

  • Plumbing
  • Sanitation
  • Fire Fighting
  • Electric and Power lines
  • Air Conditioning
  • Gas,oil, Chimney Irrigation areas
  • Solar plants
  • Parkings
  • Factories and Plants
  • Households
  • Housing complexes
  • Hospitals
  • Shopping Malls
  • Pharmaceuticals
  • Gardens and Landscapes